E469078

BX-35

Lynx Panel Meter

3 1/2 DIGIT 0.56 LED

in a 1/16 DIN Case

LYNX FAMILY

A versatile panel meter that utilizes many different types of modular plug-in signal conditioners.

General Features

External transmitters or signal conditioners can be eliminated

by directly connecting the sensor to more than 33 I-Series

Plug-in Input Signal Conditioning Modules that include:

AC Current

AC Voltage

DC Current

DC Voltage

Load Cell

Pressure

Process

Prototype

Resistance

Strain-gage

Temperature

4 to 20 mA

Pre-calibrated I-Series Input Signal Conditioning modules, that

have span or zero potentiometers, can be interchanged between

any I-Series compatible meter, without recalibration, because all

of the analog scaling and reference circuitry is self-contained with-

in the module.

24 V DC excitation is available to power external transmitters

and 5 or 10 V DC excitation is available for strain-gages, load

cells and resistance bridge type sensors.

Auto-sensing AC/DC power supply. For voltages between

85-265 V AC / 95-300 V DC (PS1) or 15-48 V AC / 10-72 V DC (PS2).

Standard red or optional green or super bright red 3 1/2-digit

0.56 LED with display range 1999 to 1999 (4000 counts).

Display brightness may be externally controlled

1/16 DIN (96 x 24mm ) case easily mounts in thin or thick

panels (up to 2).

UL Listed

Input Module Compatibility

LYNX FAMILY: More than 33 different Plug-in I-Series Input Signal Conditioners are approved for Texmates Lynx Family of meters. As shown on pages 3 to 5.

See www.texmate.com for an up to date listing.

Specifications

Input Specs:..............Depends on input signal conditioner A/D Converter:..........12 bit dual slope Accuracy:..................(0.05% of reading + 2 counts) Temp. Coeff.:.............100 ppm/C (Typical) Warm up time:...........2 minutes Conversion Rate:......3 conversions per second (Typical) Display:......................3 1/2 digit 0.56" Red LED display (std), 0.56 Green or Super Bright Red (optn).

Range 1999 to 1999 counts.

Polarity:.....................Assumed positive. Displays negative Decimal Selection:....Header under face plate, XXXX Positive Overrange:..1 (MSD) is displayed with all other dig-

its blank.

Negative Overrange: 1 (MSD) and sign are displayed with

all other digits blank.

Power Supply:...........AC/DC Auto sensing wide range supply PS1 (std)................85-265 VAC, 50-400Hz / 95-300 VDC @ 1.5W PS2.........................15-48 VAC, 50-400Hz / 10-72 VDC @ 4.0W Operating Temp.:......0 to 50 C Storage Temp:...........20 C to 70 C.

Relative Humidity:....95% (non condensing) Case Dimensions:....1/16 DIN Bezel: 96x24mm (3.78x0.95)

Depth behind bezel 122.2 mm (4.83") Plus 12.7mm (0.5) for Right-angled connector.

Weight:.......................7 oz., 9 oz when packed

Index

Case Dimensions.................................. 7 Component Layout................................. 3 Connector Pinouts................................. 2 Connectors....................................... 2 Functional Diagram................................ 2 General Features.................................. 1 I-Series Input Signal Conditioning Modules............ 3-5

Input Module Calibration Procedures................. 6-7 Input Module Compatibility........................... 1 Installation Guidelines.............................. 8 Specifications..................................... 1 Input Module Component Glossary.................... 6 Ordering Information............................... 9 Pin Descriptions................................... 2

Page 1

Functional Diagram

Hold

Test

Common

Dim/Blank

AC Neutral, DC

AC Line, + DC AC/DC Power Input

BX-35 Functional Diagram

Connector Pinouts

Connectors

Decimal Select Header

This meter comes standard with screw ter mi nal plug connections.

10 11 12

14 15

Top Catches

Release From Bottom

TO REMOVE REAR COVER

Pin Descriptions

Pins 1 to 6 - Input Module: See the individual pin out of the input signal conditioning module selected. Usually Pin 1 is the Signal Input High pin and Pin 3 is the Signal Input Low pin. All calibration and scaling functions are performed on the individual input signal conditioner module. See pages 6 and 7.

Pin 9 - Hold: If this pin is left unconnected the meter will operate in a free running mode. When this pin is connected to the Common Pin 11, the meter display will be latched. A/D conversions will continue, but the display will not be updated until Pin 9 is disconnected from Pin 11.

Pin 10 - Display Test: When this pin is connected to the Common Pin 11, all segments of the display light up and 1888 is displayed. This is used to detect any missing segments in the display.

Page 2

This meter uses plug-in type screw terminal connectors for all input and output connections. The power supply connections (pins 14 and 15) have a unique plug and socket outline to prevent cross connection. The main board uses standard right-angled connectors.

Pin 11 - Common: To Hold, Test or Dim the display, the re spec tive pins have to be connected to this Common Pin.

Pin 12 - Dim/Blank: When this pin is connected to the Common Pin

11 the display is blanked out. If it is connected through an external 1K pot, the display may be dimmed.

Pin 14 & 15 - AC/DC Power Input: These pins are the power pins of the meter and they only accept a special polarized screw terminal plug that can not be inserted into any other input socket. The standard meter has a auto sensing AC/DC power supply that operates from 85-265 VAC/95-300 VDC (PS1 Std). An optional isolated low voltage power supply that operates from 15-48 VAC/10-72 VDC

(PS2) is also available.

Component Layout

BX-35-XX-PS1 (High Voltage)

BX-35-XX-PS2 (Low Voltage)

I-Series Input Signal Conditioning Modules

Many additional input modules are available and others are constantly being developed. Check with your local distributor or www.texmate. com for updated information.

Precalibrated I-Series input modules, that have span or zero potentiometers, can be interchanged between any I-Series compatible meter, without recalibration, because all of the analog scaling and reference circuitry is self-contained within the module. Where appropriate, all the standard ranges shown are designed to be header selectable by the user, and Texmate's unique SPAN ADJUST Header facilitates scaling to almost any required engineering unit. See Input Module Component Glossary and Calibration on pages 6 and 8.

Unless otherwise specified Texmate will ship all modules precalibrated with factory preselected ranges and/or scalings as shown in BOLD type. Other precalibrated standard ranges or custom ranges may be ordered. Factory installed custom scaling and other custom options are also available (see Ordering Information, Special Options on last page).

Symbols Indicate Module Compatibility Within Meter Families

IA03: AC Milliamps Scaled RMS, 2/20/200mA AC

ALL MODELS

SOME MODELS MODEL SPECIFIC

IA01: AC Volts Scaled RMS, 200/300V AC

IA04: AC Amps Scaled RMS, 1 Amp AC IA05: AC Amps Scaled RMS, 5 Amp AC

IA02: AC Volts Scaled RMS, 200mV/2V/20V AC

IA06: AC Volts True RMS, 300V AC

Page 3

I-Series Input Signal Conditioning Modules Continued

IA07: AC Volts True RMS, 200mV/2V/20V AC

ID02: DC Millivolts, 20/50/100/200mV DC w/24V DC Exc

IA08: AC Milliamps True RMS, 2/20/200mA AC

ID03: DC Milliamps, 2/20/200mA DC w/24V DC Exc

IA09: AC Amps True RMS, 1 Amp AC IA11: AC Amps True RMS, 5 Amp AC

IA10: AC Millivolts, Scaled RMS, 100mV AC

IA12: AC Millivolt RMS Sigma Delta

ID04: DC Amps, 5A DC ID09: DC Amps, 1A DC

ID05: DC Volts 2/20/200/Custom V DC with Offset and 24V Exc.

ID07: DC Milliamps, 2/20/200mA DC with Offset and 24V Exc

ID01: DC Volts, 2/20/200V/Custom w/24V DC Exc

IF02: Line Frequency

Page 4

I-Series Input Signal Conditioning Modules Continued

IGYZ: Universal Direct Pressure (Absolute or Differential/Gage)

See below for ordering code options

IR04: Resistance 2K (Lynx only) IR05: Resistance 2K (Leopard only)

IS05: Pressure/Load Cell 20/2mV/V, 5/10V Exc 4-wire

IS06: Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire

IP01: Process Loop, 4-20mA IP02: Process Loop, 4-20mA with 24VDC EXC 091E

IP03: Process Input, 1-5V DC with Offset, 24V Exc

IT03: RTD, 100 Pt. 2/3/4-wire (-200 to 800C) IT04: RTD, 100 Pt. 2/3/4-wire (-200 to 1470F) IT05: RTD, 100 Pt. 2/3/4-wire (-199.9 to 199.9F) IT14: RTD, 100 Pt. 2/3/4-wire (-199.9 to 199.9C) 187C

IR02: 3 wire Potentiometer 1K min (0-F.S.)

IT06: Thermocouple, J Type (0-1400 F) IT08: Thermocouple, J Type (0-760 C)

IR03: Linear Potentiometer 1K min

IT07: Thermocouple, K Type (0-1999 F) IT09: Thermocouple, K Type (0-1260 C)

Page 5

Input Module Component Glossary

Input and Output Pins On most modules Pin 1 is the Signal High input and Pin 3 is the Signal Low input. Typically Pin 2 is used for Excitation Voltage output.

24V DC Output Header On some modules this header enables a 24V DC 25mA (max) Excitation/Auxiliary output to be connected to Pin 2.

INPUT RANGE Header

Range values are marked on the PCB. Typically two to four positions are provided, which are selected with either a single or multiple jumper clip. When provided, a custom range position is only functional when the option has been factory installed.

SPAN Potentiometer (Pot)

If provided, the 15 turn SPAN pot is always on the right side (as viewed from the rear of the meter).

Typical adjustment is 20% of the input signal range.

SPAN ADJUST Header

This unique five-position header expands the adjustment range of the SPAN pot into five equal 20% steps, across 100% of the input Signal Span. Any input Signal Span can then be precisely scaled down to provide any required Digital Display span from 1999 counts to 001 (one count).

SPAN RANGE Header

When this header is provided it works in conjunction with the SPAN ADJUST Header by splitting its adjustment range into a Hi and a Lo range. This has the effect of dividing the adjustment range of the SPAN pot into ten equal 10% steps across 100% of the input Signal Span.

Page 6

ZERO Potentiometer (Pot)

If provided, the ZERO pot is always to the left of the SPAN pot (as viewed from the rear of the meter). Typically it enables the input signal to be offset 5% of full scale (-100 to +100 counts).

ZERO OFFSET RANGE Header When provided, this three position header increases the ZERO pots capability to offset the input signal, to 25% of the digital display span.

For example a Negative offset enables a 1 to 5V input to display 0 to full scale. The user can select negative offset, positive offset, or no offset (ZERO pot disabled for two step non-interactive span and offset calibration).

ZERO ADJUST Header

When this header is provided, it works in conjunction with the ZERO OFFSET RANGE Header, and expands the ZERO pots offset capability into five equal negative steps or five equal positive steps. This enables virtually any degree of input signal offset required to display any desired engineering unit of measure.

Input Module Calibration

Basic standard range calibration of direct reading modules that utilize either Auto Zero or a ZERO pot, an INPUT RANGE Header and or a SPAN pot.

1 If the module has an INPUT RANGE Header, reposition the jumper

clip to select the desired input signal range.

2. Apply a zero input or short the input pins. The display will auto zero, or if the module has a ZERO pot, it should be adjusted until the display reads zero.

3 Apply a known input signal that is at least 20% of the full scale input range and adjust the SPAN pot until the display reads the exact input value.

4 Decimal Points. The selection or positioning of decimal points has

no effect on the calibration of the modules

Wide range scaling, in engineering units not requiring offsets, with modules that utilize auto-zero or a ZERO pot, a SPAN RANGE Header and or a SPAN ADJUST Header.

Texmates unique SPAN ADJUST and SPAN RANGE Headers provide the circuit equivalent of an ultra-precision one megohm 75 or

150 turn potentiometer that can infinitely scale down any Input Signal SPAN to provide any full scale Digital Display Span from 1999 (counts) to 001 (one count).

Input Module Calibration Procedures Continued

If the module has an INPUT RANGE Header, and the required full scale Digital Display Span (counts) is to be larger than the directly measured value of the input Signal Span, then the next lower range on the INPUT RANGE Header should be selected. The resulting over range Signal Span is then scaled down, by selecting the position of the SPAN RANGE Header and or the SPAN ADJUST Header, which will reduce the input Signal Span to a percentage, that the required Digital Display Span can be reached by calibration with the SPAN pot.

Example A: 0 to 10 V to read 0 to 1800 gallons.

Signal Span = 10V, Digital Display Span = 1800 counts

1 Select the 2 V INPUT RANGE Header position. This will provide a digital display of 1800 counts with an input of only 1.8 V which is (1.810)=18% of the examples 10 V Signal Span.

2 To scale down the Signal Span to 18% select the 20% Signal Span position on the SPAN ADJUST Header (position 1) or if the module has a SPAN RANGE Header, select (LO Range) and 20% Signal Span position on the SPAN ADJUST Header (position 2).

3 Apply a zero input or short the input pins. The display will auto zero, or if the module has a ZERO pot, it should be adjusted until the display reads zero.

4 Apply 10 V and adjust the SPAN pot until the display reads 1800.

Large offset scaling and calibration of process signal inputs with modules that utilize ZERO ADJUST Headers and or ZERO OFFSET RANGE Headers.

Texmates unique ZERO OFFSET RANGE Header enables the use of a simple two step scaling and calibration procedure for those process signals that require large offsets. This eliminates the back and forth interaction, between zero and span settings, that is often required to calibrate less finely engineered products.

The first step is to set the ZERO OFFSET RANGE Header to the center position (No Offset) and scale down the Input Signal Span to a percentage that will enable calibration with the SPAN pot to reach the required Digital Display Span.

The second step is to set the ZERO ADJUST and or ZERO OFFSET RANGE Header to provide a positive or negative offset of sufficient counts that calibration with the ZERO pot will offset the Digital Display Span to produce the required digital reading.

Example B: 1 to 5 V to read 100 to 1500 C.

Signal Span = 4V, Digital Display Span = 1600 counts

1 If the module has an INPUT RANGE Header the 2 V position should be selected. This will provide a digital display of 1600 counts for an input of 1.6 V which is (1.6 4) = 40% of the examples 4 V signal span. To scale down the Signal Span to 40% select the 40% Signal Span position on the SPAN ADJUST Header (position 2).

2 If the module is a Process Input 1-5 V DC type, select the (Hi Range) position on the SPAN RANGE Header and the 100% Signal Span position on the SPAN ADJUST Header (position 5, max increase).

This will provide a digital display of 1600 counts for an input of 4V which is 100% of the examples 4V Signal Span.

3 Set the ZERO OFFSET RANGE Header to the center position (no offset). Apply 1 V and adjust the SPAN pot until the display reads

400. A 4V input would then read 1600 counts.

4 Set the ZERO OFFSET RANGE Header to the negative offset position. If the module has a ZERO ADJUST Header select the position that will provide a negative offset of 500 counts. Apply 1 V and adjust the ZERO pot until the display reads 100. Apply 5 V and check that the display reads 1500.

Example C: 4 to 20 mA to read 00.0 to +100.0% Signal Span = 16 mA, Digital Display Span = 1000 counts.

1 The full scale Signal Span of the Process Input 4-20 mA modules is

0 to 20 mA for a full scale Digital Display Span of 0 to 2000 counts.

This will provide a digital display of 1000 counts with an input of only

10 mA which is (1016)=62.5% of the examples 16 mA signal span.

2 To scale down the Signal Span to 62.5% select the (Hi Range) Position on the Span Range Header and the 70% Signal Span position on the SPAN ADJUST Header (position 2).

3 Set the ZERO OFFSET RANGE Header to the center position (no offset). Apply 4 mA and adjust the SPAN pot until the display reads

250. A 16 mA input would then read 1000 counts.

4 Set the ZERO OFFSET RANGE Header to the positive offset position. If the module has a ZERO ADJUST Header select the position that will provide a negative offset of 250 counts.

Apply 4 mA and adjust the ZERO pot until the display reads 000.

Apply 20 mA and check that the display reads 1000. Select decimal point 1XXX to display 00.0 to 100.0.

Case Dimensions

Page 7

Installation Guidelines

Installation

1. Install and wire meter per local applicable codes/regulations, the particular application, and good installation practices.

2. Install meter in a location that does not exceed the maximum operating temperature and that provides good air circulation.

3. Separate input/output leads from power lines to protect the meter from external noise. Input/output leads should be routed as far away as possible from contactors, control relays, transformers and other noisy components. Shielding cables for input/output leads is recommended with shield connection to earth ground near the meter preferred.

4. A circuit breaker or disconnect switch is required to disconnect power to the meter. The breaker/switch should be in close proximity to the meter and marked as the disconnecting device for the meter or meter circuit.

The circuit breaker or wall switch must be rated for the applied voltage (e.g., 120VAC or 240VAC) and current appropriate for the electrical application (e.g., 15A or 20A).

5. See Case Dimensions section for panel cutout information.

6. See Connector Pinouts section for wiring.

7. Use 28-12 AWG wiring, minimum 90 C (HH) temperature rating. Strip wire approximately 0.3 in. (7-8 mm).

8. Recommended torque on all terminal plug screws is 4.5 lb-in (0.51 N-m).

Page 8

BASIC MODEL #

DISPLAY

POWER SUPPLY

INPUT MODULES

ANALOG OUTPUT

OPTIONS / ACCESSORIES

OA____

Ordering Information

BASIC MODEL #

DISPLAY

POWER SUPPLY

INPUT MODULES

OPTIONS / ACCESSORIES

BX-35

OA____

Add to the basic model number the order code suffix for each standard option required. The last suffix is to indicate how many different special options and or accessories that you may require to be included with this product.

Ordering Example: BX-35-DR-PS1-IA01-OA2, the 2 OAs are, CR-CHANGE and a 75-DMTC96X24, + N/C + N/C + 40 + 8+ 2.50 = POWER SUPPLY

BASIC MODEL #

INPUT MODULES

RELAY OUTPUT

DISPLAY

OPTIONS / ACCESSORIES

BASIC MODEL NuMBER

BX-35...

96x24mm, Lynx, 3.5 Digit.....................

Standard Options for this Model Number

Order Code Suffix

Description

List

DISPLAY

DR... Red LED, 0.56 inch high........................... N/C DB... Superbright Red LED, 0.56 inch high............ DG... Green LED, 0.56 inch high....................

POWER SuPPLY

PS1.. 85-265VAC/95-300VDC............................ N/C PS2.. 15-48VAC/10-72VDC........................

INPuT MODuLES (Partial List. See www.texmate.com) Unless otherwise specified Texmate will ship all modules pre calibrated with factory preselected ranges and/or scalings as shown in BOLD type.

450 State Place Escondido, CA 92029 Tel: 1-760-598-9899 USA 1-800-839-6283 Thats 1-800-TEXMATE Fax: 1-760-598-9828 Email: [email protected] Web: www.texmate.com

OA____

IP03..Process Input, 1-5V DC(0-100.00) w/Offset, 24V Exc...... IR02.. 3-Wire Potentiometer 1K min (0-F.S.)................... IR03.. Linear Potentiometer, 3-wire, 1K min................... IR04..Resistance 2K................................. IS04..Pressure Ext Exc., 20/2mV/V, 4/6wire................ IS05.. Pressure/Load Cell 20/2mV/V, 5/10V Exc 4-wire........... IS06.. Pressure/Load Cell Ext Exc., 20/2mV/V, 4-wire............ IT03...RTD, 100 Pt. 2/3/4-wire (-200 to 800C)............... IT04...RTD, 100 Pt. 2/3/4-wire (-200 to 1470F).............. IT05...RTD, 100 Pt. 2/3/4-wire (-190.0 to 199.0F)............ IT06...Thermocouple, J Type (0-1400 F).................... IT07...Thermocouple, K Type (0-1999F).................... IT08...Thermocouple, J Type (0-760 C)..................... IT09...Thermocouple, K Type (0-1260C).................... IT14...RTD, 100 Pt. 2/3/4-wire (-199.0 to 199.0C)............

Special Options and Accessories (OAs)

Part Number

Description

List

SPECIAL OPTIONS (Specify Input & Req. Reading) CR-CHANGE.. Calibrated Range Change to another Standard Range.. CS-3/3.5/4.... Custom display scaling within std.ranges....... CSS-SETUP... NRC to set-up custom special scaling beyond the std. range.. CSS-34/INSTL. Installation, specify serial #CSS...........

For product details visit www.texmate.com

Local Distributor Address

Page 9

About TexMate

Texmate is an American manufacturer of high durability industrial grade panel meters, bar graphs, and transducers. Texmate's meters are frequently equipped with relays and various signal outputs for industrial automation applications and are known for their extremely long service life.