Case Dimensions

Bezel: 96x48 mm (3.78"x1.89")
Depth behind bezel: 117 mm (4.61")
Plus 11.8 mm (0.47") for Right-angled connector or plus 20 mm (0.79") for Straight-thru connector.

Panel Cutouts

Loose Fitting: 92x45 mm (3.62"x1.77")
Snug Fitting: 91.6x43.4 mm (3.6"x1.71")

Download 96x48 mm (3.78"x1.89") 1/8 DIN Detailed Case Dimensions and Panel Cutouts (PDF).

Available Meters:

  • Function Specific Panel Meters, Bargraphs and Controllers »
    • DX-35-ACA DX-35-ACA
      AC amperes, Scaled RMS. 5 Amp (built-in shunt), 3.5 digit
      True RMS optional
    • DX-35-ACV DX-35-ACV
      • A 3.5 DIGIT AC Volt Meter with either Scaled RMS VAC (IA01) or True RMS VAC (IA06) Input Modules up 300VAC.
      • Universal Auxiliary Switching Power Supply 85-265 VAC / 95-365 VDC @ 50/60Hz Standard or Optional 15-48 VAC / 10-72 VDC.
      • Case: 1/8 DIN size 96X48 mm Depth 128.8 mm
      • Meter to be used on Power Industries, Scalable to read any Potential Transformer Primary rated up to 2KV with 110,120 or 240 Secondary Volts.
    • DX-35-CL DX-35-CL
      Process 4 to 20 mA, Fully user scalable, 3.5 digit
      excitation optional
    • DX-35-DCA DX-35-DCA
      DC amp meters are specifically designed to display the output of all popular shunts 50mV, 60mV,100mV and 120mV.
      3.5 digit
    • DX-35-DCV DX-35-DCV
      DC volts selectable from 2 V / 20 V / 200 V, 3.5 digit
    • DX-35-HZ DX-35-HZ
      Line frequency 199.9 or 500 Hz up to 700V AC input, 3.5 digit
    • DX-35-RTD-C DX-35-RTD-C
      3.5 digit, Pt.,100 Ohm in °C, 1° resolution (-190°C to 190°C)
    • DX-35-RTD-F DX-35-RTD-F
      DPM, Pt.,100 Ohm in °F, 1° resolution
    • DX-35-TC-JF DX-35-TC-JF
      J Thermocouple order, °F, 3.5 digit, 0.56" LED
    • DX-35-TC-KF DX-35-TC-KF
      K Thermocouple order, °F, 3.5 digit, 0.56" LED
    • DX-40-ACV DX-40-ACV
      • A 4 DIGIT AC Volt Meter with either Scaled RMS VAC (IA01) or True RMS VAC (IA06) Input Modules up 300.0VAC.
      • Universal Auxiliary Switching Power Supply 85-265 VAC / 95-365 VDC @ 50/60Hz Standard or Optional 15-48 VAC / 10-72 VDC.
      • Case: 1/8 DIN size 96X48 mm Depth 128.8 mm
      • Meter to be used on Power Industries, Scalable to read any Potential Transformer Primary rated up to 10 KV with 110,120 or 240 Secondary Volts.
    • DX-45-ACA DX-45-ACA
      5 amp AC current meter, 4.5 Digit with 0.56" or 0.8" LEDs
      True RMS optional
    • DX-45-CL DX-45-CL
      Process 4 to 20 mA, Fully user scalable, 4.5 digit
      excitation optional
    • DX-45-DCA DX-45-DCA
      DC voltage: DC mV selectable from 50 mV / 100 mV / 200 mV, 4.5 digit
    • DX-45-DCV DX-45-DCV
      DC volts selectable from 2 V / 20 V / 200 V, 4.5 digit
      zero offset optional
  • Tiger Panel Meters, Bargraphs and Process Controllers / Micro PLC »
    • DI-50E DI-50E
      96x48mm, Tiger 320, 5 Digit, E Version
    • DI-50T DI-50T
      96x48mm, Tiger 320, 5 Digit, T Version
    • DI-60AE DI-60AE
      96x48mm, Tiger, 6 Digit, Alphanumeric, E Version
    • DI-60AT DI-60AT
      96x48mm, Tiger, 6 Digit, Alphanumeric, T Version
    • DI-60AT5C DI-60AT5C
      96x48mm, Tiger, 6 Digit, Alphanumeric, 5 Controls, T Version
    • DI-60E DI-60E
      96x48mm, Tiger, 6 Digit, E Version
    • DI-60T DI-60T
      96x48mm, Tiger, 6 Digit, T Version
  • Leopard Panel Meters, Meter Bargraphs and Process Controllers »
    • DL-40 DL-40
      96x48mm, Leopard, 4 Digit
    • DL-40F DL-40F
      96x48mm, Leopard, 4 Digit, Frequency
    • DL-40H DL-40H
      96x48mm, Leopard, 4 Digit, Temperature
  • Lynx Digital Panel Meters, Indicators, and Bargraph Controllers »
    • DX-35 DX-35
      96x48mm, Lynx, 3.5 Digit
    • DX-40 DX-40
      96x48mm, Lynx, Large 4 Digit
    • DX-45 DX-45
      96x48mm, Lynx, 4.5 Digit